HY-IM係列節能吸棉風機
HY-IM series ofenergy-saving suction fan
結構特點
Structural characteristics
HY-IM-I 吸棉風機配置為1.1W,替代了原紗機2.2KW電機的吸棉風機,保持原來的笛管真空度不變,而能耗降低40%以上,節能效果明顯。該風機結構緊湊,運行可靠,安裝方便,氣動性能優良,外型如圖:
HY-IM-I Suction fan motor configured to 1.1kw,replaced the former cotton spinning2.2kw motor sucion fan to keep the original pipe vacuum tube remain uncheanged, while more than 40% reduction in energy consumption, energy-saving effect evident. The fan compact,reliable,easy installation,excellentaerodynamic performance,appearance,shchas RIghe:
風機性能參數
Fan performance parameters
風機型號 (Fan Model) | 風量 (Airflow) | 全壓 (Total Pressure) | 額定功率 (Rated) | 額定電流 (Rated) | 實際電流 (Actual Current) |
HY-IM-I | 1980m3/h | 1680pa | 1.1kw | 2.58A | 1.8-2.0A |
HY-IM-II | 2200m3/h | 1900pa | 1.5kw | 3.5A | 2.3-2.5A |
HY-IM-III | 2800m3/h | 2400pa | 4kw | 8.7A | 6.5-7.4A |
備注:*HY-IM-I適用於420錠至456錠細紗機 *HY-IM-II適用於480錠至516錠細紗機 *HY-IM-III適用於1080錠至1200錠細紗機 |
安裝與調試
Installation and commissioning
1、風機整機出廠,安裝方法與原細紗機吸棉風機裝法相同。
注意周邊密封。
2、注意將原電機的電器保護更換為與1.1Kw電機相匹配的保護裝置。
3、電機轉向如標牌上箭頭所示方向。
維護保養
Maintenance
1、定期檢查吸棉風機濾網是否損壞,風機葉輪是否掛花。
2、定期檢查風機殼體與細紗機接觸是否良好,防止漏風降低吸棉笛管真空度。
3、電機定期維護保養。